TSI Alnor EBT721 EBT 721 Air Balancing Balometer Flow Capture Hood

Alnor EBT721 EBT 721 Air Balancing Balometer Flow Capture Hood

The Alnor Model EBT721 Air Balancing Balometer Flow Hood is an electronic multipurpose air balancing instrument for measuring the volume of air flow at diffusers and grills.

 

The Alnor EBT721 Balometer Electronic Balancing Tool includes a detachable multi purpose digital manometer that can be utilized with a wide range of common balance and test tools such as air foil, pitot, relative humidity, and temperature probes, or a 16 point velocity matrix. It is the professional’s choice for facilities personnel and contractors due to its light weight and ergonomic design.

 

The EBT720 is one of the most versatile, advanced, and user friendly manometers available on the market today. The auto zeroing feature enables you to take measurements all through the day. The velocity matrix accessory is perfect for measuring face velocity through coils, filters, as well as other specialized spaces.

 

Applications include HVAC testing, thermal comfort studies, balancing, adjusting, as well as air volume measurements.

 

EBT721 Features:
  • Data logging
  • Pre assembled hood frames save time on site
  • Multiple hood sizes available
  • Measurement range: 25 to 2500 cfm (42–4250 m3/h)
  • Automatic density correction

Standard Equipment 

  • 2 x 2 foot capture hood frame base
  • Detachable digital manometer
  • Wheeled luggage style carrying case
  • 18 inch Pitot probe
  • 2 Static pressure probes
  • Two 8 foot Norprene tubes
  • LogDat1 software for generating reports
  • Serial interface cable
  • Neck strap
  • 4 AA rechargeable NiMH batteries
  • NIST calibration and manual

EBT721 Specifications

Velocity Range

 

Pitot probes

25 to 8,000 ft/min (0.125 to 40 m/s)

Air flow probe

25 to 5,000 ft/min (0.125 to 25 m/s)

Velocity matrix

25 to 2,500 ft/min (0.125 to 12.5 m/s)

Accuracy

±3 percent of reading ±7 ft/min (±0.04 m/s) at
velocities >50 ft/min (>0.25 m/s)

Units

ft/min, m/s

Resolution

1 ft/min (0.01 m/s)

Pressure

 

Differential pressure

±15 in. H2O (±3735 Pa);
150 in. H2O (37.5 kPa),
maximum safe operating pressure

Absolute pressure

15 to 40 in. Hg (356 to 1016 mm Hg)

Accuracy

±2 percent of reading ±0.001 in. H2O (±0.25 Pa)
static and differential; ±2 percent of reading absolute

Units

in. H2O, in. Hg, Pa, hPa, kPa, mm Hg,
cm Hg, mm H2O, cm H2O

Resolution

0.00001 in. H2O (0.001 Pa) static and
differential; 0.01 in. Hg (1 mm Hg) absolute

Volume

 

Range

25 to 2,500 ft

3/min (42 to 4250 m3/h) capture hood

Accuracy

±3 percent of reading ±7 ft3/min (±12 m3/h) at
flows >50 ft3/min (>85 m3/h)

Units

ft3

/min, m3/h, m3/min, l/s

Resolution

1 ft

3/min (1 m3/h)

RH

 

Range

0 to 95 percent RH temperature/RH probe

Accuracy

±3 percent RH

Resolution

0.1 percent RH

Temperature

 

Sensor in base

40 to 140 degrees F (4.4 to 60 degrees C)

Temperature probe

-40 to 250 degrees F (-40 to 121 degrees C)

Temperature/RH probe

14 to 140 degrees F (-10 to 60 degrees C)

Accuracy

±0.5 degrees F (±0.3 degrees C)
from 32 to 160 degrees F (0 to 71 degrees C)

Units

degrees F, degrees C

Resolution

0.1 degrees F (0.1 degrees C)

Instrument Temperature Range

 

Operating

40 to 140 degrees F (4.4 to 60 degrees C)

Storage

-4 to 160 degrees F (

$2,655.00
3M
Accuform Signs
AEMC
Air Systems International
Allegro
Allegro Industries
Amprobe
ARCHOS
Bacharach
Bradley
Building Health Check, L.L.C.
Bullard
Capital Safety
Carlisle
Cool Machines
CorDEX Instruments
Delmhorst
DeWALT
DuPont
E Instruments
EDTM
Electrophysics
Enerac
Extech
Falltech
Fieldpiece
FLIR
Fluke
Fomo Products, Inc.
Generac
Gillette Generators
Guardian
Hardcast
Hioki
Honeywell
Ideal
Infraspection Institute
Intec
Irwin
Kanomax
Kimo
Knipex
Krendl
Lighthouse
MAVCAP Industries Inc.
Megger
Miller
MK Diamond
MSA Safety
Net Zero
NIKRO Industries, Inc.
NWi Northwest Instrument
Ocean Industrial Supply
Pro Built Tools
Protective Industrial Products, Inc.
Radians
Rapid Care
Reed
Retrotec
Ridge Rock
Safewaze
Salisbury
Schaefer Ventilation Equipment
SENSIT Tech.
Set Go
TEC
TED
Test Products International
Testo
Toshiba
Tramex
TSI
UEI
Voltec
Wera Tools, Inc.
Zipwall
Home > Balometer - Flow Hood
TSI Alnor EBT721 EBT 721 Air Balancing Balometer Flow Capture Hood
TSI Alnor EBT721 EBT 721 Air Balancing Balometer Flow Capture Hood
Item Id: 2549
Review this item Review this item
Your Price:
$2,655.00
Availability:
Not for Sale
Email a friend Email a friend
Description

Alnor EBT721 EBT 721 Air Balancing Balometer Flow Capture Hood

The Alnor Model EBT721 Air Balancing Balometer Flow Hood is an electronic multipurpose air balancing instrument for measuring the volume of air flow at diffusers and grills.

 

The Alnor EBT721 Balometer Electronic Balancing Tool includes a detachable multi purpose digital manometer that can be utilized with a wide range of common balance and test tools such as air foil, pitot, relative humidity, and temperature probes, or a 16 point velocity matrix. It is the professional’s choice for facilities personnel and contractors due to its light weight and ergonomic design.

 

The EBT720 is one of the most versatile, advanced, and user friendly manometers available on the market today. The auto zeroing feature enables you to take measurements all through the day. The velocity matrix accessory is perfect for measuring face velocity through coils, filters, as well as other specialized spaces.

 

Applications include HVAC testing, thermal comfort studies, balancing, adjusting, as well as air volume measurements.

 

EBT721 Features:
  • Data logging
  • Pre assembled hood frames save time on site
  • Multiple hood sizes available
  • Measurement range: 25 to 2500 cfm (42–4250 m3/h)
  • Automatic density correction

Standard Equipment 

  • 2 x 2 foot capture hood frame base
  • Detachable digital manometer
  • Wheeled luggage style carrying case
  • 18 inch Pitot probe
  • 2 Static pressure probes
  • Two 8 foot Norprene tubes
  • LogDat1 software for generating reports
  • Serial interface cable
  • Neck strap
  • 4 AA rechargeable NiMH batteries
  • NIST calibration and manual

EBT721 Specifications

Velocity Range

 

Pitot probes

25 to 8,000 ft/min (0.125 to 40 m/s)

Air flow probe

25 to 5,000 ft/min (0.125 to 25 m/s)

Velocity matrix

25 to 2,500 ft/min (0.125 to 12.5 m/s)

Accuracy

±3 percent of reading ±7 ft/min (±0.04 m/s) at
velocities >50 ft/min (>0.25 m/s)

Units

ft/min, m/s

Resolution

1 ft/min (0.01 m/s)

Pressure

 

Differential pressure

±15 in. H2O (±3735 Pa);
150 in. H2O (37.5 kPa),
maximum safe operating pressure

Absolute pressure

15 to 40 in. Hg (356 to 1016 mm Hg)

Accuracy

±2 percent of reading ±0.001 in. H2O (±0.25 Pa)
static and differential; ±2 percent of reading absolute

Units

in. H2O, in. Hg, Pa, hPa, kPa, mm Hg,
cm Hg, mm H2O, cm H2O

Resolution

0.00001 in. H2O (0.001 Pa) static and
differential; 0.01 in. Hg (1 mm Hg) absolute

Volume

 

Range

25 to 2,500 ft

3/min (42 to 4250 m3/h) capture hood

Accuracy

±3 percent of reading ±7 ft3/min (±12 m3/h) at
flows >50 ft3/min (>85 m3/h)

Units

ft3

/min, m3/h, m3/min, l/s

Resolution

1 ft

3/min (1 m3/h)

RH

 

Range

0 to 95 percent RH temperature/RH probe

Accuracy

±3 percent RH

Resolution

0.1 percent RH

Temperature

 

Sensor in base

40 to 140 degrees F (4.4 to 60 degrees C)

Temperature probe

-40 to 250 degrees F (-40 to 121 degrees C)

Temperature/RH probe

14 to 140 degrees F (-10 to 60 degrees C)

Accuracy

±0.5 degrees F (±0.3 degrees C)
from 32 to 160 degrees F (0 to 71 degrees C)

Units

degrees F, degrees C

Resolution

0.1 degrees F (0.1 degrees C)

Instrument Temperature Range

 

Operating

40 to 140 degrees F (4.4 to 60 degrees C)

Storage

-4 to 160 degrees F (

Related Items
TSI Alnor ABT703 ABT 703 Balometer Capture Hood CFM Instruments
TSI Alnor ABT703 ABT 703 Balometer Capture Hood CFM Instruments
Average Rating 0 Review(s)
Your Price: $2,075.00
TSI Alnor 6200F 6200 F LoFlo Balometer Flow Capture Hood
TSI Alnor 6200F 6200 F LoFlo Balometer Flow Capture Hood
Average Rating 0 Review(s)
Your Price: $1,460.93
TSI Alnor 6200E 6200 E LoFlo Balometer With No Hood
TSI Alnor 6200E 6200 E LoFlo Balometer With No Hood
Average Rating 0 Review(s)
Your Price: $1,445.67
TSI Alnor 6200D 6200 D LoFlo Balometer Flow Capture Hood
TSI Alnor 6200D 6200 D LoFlo Balometer Flow Capture Hood
Average Rating 0 Review(s)
Your Price: $1,385.00
TSI Alnor 6463CFM 6463 CFM Standard Balometer Flow Capture Hood
TSI Alnor 6463CFM 6463 CFM Standard Balometer Flow Capture Hood
Average Rating 0 Review(s)
Your Price: $2,508.84
TSI Alnor 6461CFM 6461 CFM Standard Balometer Flow Capture Hood
TSI Alnor 6461CFM 6461 CFM Standard Balometer Flow Capture Hood
Average Rating 0 Review(s)
Your Price: $2,490.00
Browse Similar Items
Balometer - Flow Hood > Alnor Flow Hoods / Balometers