OX5042 2150.21 Specifications |
User Interface |
Display | 3.5 inch color LCD TFT screen, Resolution 320 x 240 LED backlit |
Display modes | 2500 real acquisition pts. on-screen |
Curve Display on-screen | 2 curves, 2 references, memory traces or math calculation |
Command types | Direct front panel adjustments & on screen menu with browser (secondary & principal with no hidden menu) |
Interactive help | English, Dutch, Polish, Finnish, Russian, Rumanian, Swedish, Italian, Spanish, German, French |
Oscilloscope |
Deflection (Vertical) |
Bandwidth | 40MHertz |
Bandwidth limiter | 5 kHertz, 1.5MHertz |
Channels | 2 totally isolated |
Input impedance | 1 MOhms +/- 0.5 percent, approximately 17pF |
Max. input voltage | 600 Volts CATIII Derating -20 deciBels / decade from 100kHertz |
Vertical sensitivity | 5 milliVolts - 200 Volts / div |
Deflection (Horizontal) |
Sweep speed | 25ns / div - 200 sec / div Roll Mode 100 millisecons - 200 sec./ div |
Horizontal zoom factor | x5, x2, x1 |
Triggering |
Modes | one shot, triggered, triggered Roll, Automatic |
Type | Edge - pulse width (20ns - 20s) |
Coupling | DC or AC (depends on coupling of triggering channel) LF, HF or noise rejection |
Sensitivity | ≤1.2 div p-p to 40MHertz max. |
Memory (digital) |
Max. sample rate | 2 GS / s with ETS mode 50 MS / s with 1-shot mode each channel |
Resolution (Vertical) | 9bits |
Memory depth | 2500 pts. / channel |
Storage | 2MB file storage - (.trc) trace, (.txt) text, (.cfg) configuration, (.bmp) image files |
GLITCH mode | A Duration of ≥ 20ns with 1250 Min / Max pairs |
Display mode | (factors 2 - 64) Averaging, (vector) XY, Envelope |
Other functionality |
MATH | subtraction, addition, multiplication, Channel inversion & (adjustable scaling) division |
Cursor measurement | 2: dV, T, V, dt simult. 4 digit display res. |
Automatic measurement | 18 level or time & phase |
Multimeter |
General | 2 ch., 8000 ct display plus min / max bar graph, Graphical recordings for 2700 measurements 5 minutes - 1 month |
Operation modes | Aelative or Absolute display (deviation, absolute, ref percent, ref), Monitoring (Avg, Max, Min, instantaneous) |
DC, AC & AC + DC voltage | from 600milliVolts - 600 Volts RMS, 800milliVolts - 800 VoltsDC - Volts DC accuracy - 1 percent of reading +20D -50 kHertz bandwidth |
Resistance | 80 - 32 MOhms - accuracy 2 percent R +10D -10 millisecond quick continuity testing |
Capacitance | 5 nF - 5 mF basic accuracy 2 percent reading +10D |
Other measurement | rotational speed, Frequency, 3.3 Volt diode testing, temp. measurements (w/ infrared probe or K thermocouple) |
Power |
Measurement | Single phase & balanced 3-phase active power (w/ or w/ out neutral), simultaneous current display |
Harmonic Analyser |
Multichannel | 31 orders, frequency 40 - 450 Hertz, 2 ch. |
Simultaneous measurement | Total VoltsRMS, THD & selected order (percent fundamental, phase, Volts RMS, frequency) |
General |
Screen shots | 100 files standard .bmp format |
PC communications | optical USB Isolated interface - Optional SX-Metro PC software - version CK |
Power | 6 AA NiMh or 6 LR6 batteries - Battery operation time 8.5 hours - Universal isolated mains adapter Fast charging 2.5 hrs |
EMC / Safety | IEC61010-1 Compliant Ed3 - 600Volts CATIII EMC compliant with EN61326-1, 2006 & EN61000-3, 2001 |
Mechanical | 214 x 110 x 57 millimeterws - 1.2 kilograms w/ batteries, IP54 protection, elastomer casing |