Kimo AQ 200 Specifications
Sensor Elements
Connections for Instrument
On topsideTwo secured mini DIN connectors accommodate SMART Plus test probesLeftOne USB port - EIG cable (only)One plug - power supply
Modular Connection
Display
Housing
shock proof IP54 ABS
Keypad
5 keys, Metal coated, 1 joystick
Compliance
NF-EN-61326-1 norm Electromagnetical compatibility
Power
4 alkaline 1.5 Volt batteries LR6 (Included)
Operation Environment
Neutral Gas
Operation Temp.
0 - 122 deg. F (0 - 50 deg. C)
Storage Temp.
-4 - 176 deg. F (-20 - 80 deg. C)
Automatic Shut Down
0 - 120 minutes Adjustable
Weight
12 ounces (340 grams)
Languages
English, Spanish, German, Dutch, French, Swedish, Portugese, Italian, Danish, Finn, and Norwegian
AQ 200 Probe Specifications
Measuring Units
Measuring Ranges
Accuracy
Resolutions
CURRENT / VOLTAGE
V, mA
from 0 to 2,5 Vfrom 0 to 10 Vfrom 0 to 4/20 mA
+/- 2mV+/- 10mV+/- 0.01mA
0.001 V0.01 V0.01 mA
THERMOCOUPLE (See related datasheet)
deg. C, deg. F
K : from -200 to 1,300 deg. CJ : from -100 to 750 deg. CT : from -200 to 400 deg. C
+/- 1,1 deg. C or +/- 0,4 percent of reading+/- 0,8 deg. C or +/- 0,4 percent of reading+/- 0,5 deg. C or +/- 0,4 percent of reading
0.1 deg. C0.1 deg. C0.1 deg. C
Climatic conditions
Hygro.
percentRH
From 5 to 95 percentHR
Accuracy** (Repeatability, linearity,hysteresis) :+/- 1,8 percentRH (from 15 deg. C to 25 deg. C)Factory calibration uncertainty: +/- 0,88 percentRHTemperature dependence : +/- 0.04 x (T-20) percentRH (if T<15 deg. C or T>25 deg. C)
0.1 percentRH
Temp.Air pressure
deg. C, deg. FhPa
From -20 to +80 deg. CFrom 800 to 1100 hPa
+/- 0.4 percent of reading +/- 0.3 deg. C+/- 3 hPa
0,1 deg. C1 hPa
CO / Temperature
Temp.CO
deg. C, deg. Fppm
From -20 to +80 deg. CFrom 0 to 200 ppmFrom 0 to 5000 ppm
+/- 0.3 percent of reading +/- 0.25 deg. C+/- 3 ppm+/- 1.5 percent of reading
0,1 deg. C0,1 ppm
CO2 / Temperature
Temp.CO2
From -20 to +80 deg. CFrom 0 to 5000 ppm
+/- 0.3 percent of reading +/- 0.25 deg. C+/- 3 percent of reading or +/- 50ppm
0,1 deg. C1 ppm
CO2 / Temperature/ Hygrometry
Temp.CO2Hygro.
deg. C, deg. Fppm percentRH
From -20 to +80 deg. CFrom 0 to 5000 ppmFrom 5 to 95 percentHR
+/- 0.3 percent of reading +/- 0.25 deg. C+/- 3 percent of reading or +/- 50ppmSee Climatic conditions module
0,1 deg. C1 ppm0,1 percentRH
Omnidirectionnal probe (Air velocity / Temperature / Hygrometry)
Air velocityTemp.Hygro.
m/s deg. C, deg. F percentRH
From 0 to 5 m/sFrom -20 to +80 deg. CFrom 5 to 95 percentHR
+/- 3 percent of reading +/- 0.05 m/s+/- 0.3 percent of reading +/- 0.25 deg. CSee Climatic conditions module
0,01 m/s0,1 deg. C0,1 percentRH
Pt100 Smart-plus or wireless probes (See related datasheet)
From -50 to 250 deg. C(According to model)
+/- 0,3 percent of reading +/- 0.25 deg. C(According to model)
0,01 deg. C